Plastic Rotary Damper
Xiamen Sunled is rotary damper manufacturer. This plastic rotary damper for smart toilet pump is designed for the automatic hinge of intelligent toilet lids and seats, enabling full automation of opening and closing.
Our rotary damper for smart toilet seat is small size, high torque,DC motor type, can electrically open and close the toilet seat or cover, low noise, durable. OEM/ODM is acceptable.
Rotary Damper for Smart Toilet Seat
1.Scope
1-1 This damper(SLD-5) for smart toilet pump designed for the automatic hinge of intelligent toilet lids and seats, enabling full automation of opening and closing.
This configuration manual provides instructions on the performance and usage conditions of the electric damper.
1-2 Quantity of Application: One unit is used for each toilet lid/seat.
2.Specification
Item | Spec. | Remark |
Rated Voltage | DC12V |
|
Power Consumption | 12W Max |
|
Operating Temperature | 0°C~40°C | Ice free & Dew Free |
Storage Temperature | -10°C~50°C | Ice free & Dew Free |
Operating Humidity | 45~85%RH | Ice free & Dew Free |
Operating Angle | 0°~120° |
|
Rotation Direction | CW | R: CLOSE, L:OPEN DIRECTION |
Load Reversal Direction | CCW | From Output Shaft |
Output Torque (Rated Load) | 2.8N·m Min | CCW |
Mechanical Strength (strength of output shaft and mounting components) | The output shaft and mounting components must not be subjected to external forces exceeding 5 N·m | CCW
|
Motor Type | DC MOTOR |
|
3.Basic Performance
Item | Spec. | Remark | ||
Insulation Class | Class A |
| ||
Driving Voltage | DC12V±5% |
| ||
Operating Current | 1.5A Min | Max Current of Motor | ||
No-load Rotation Speed | 19.5RPM |
| ||
Open Time | 2.5±1 sec | Rated Load, CCW、Duty100% | ||
Close Time | 3± 1sec | meet the combined SET control conditions | ||
Signal Part Voltage | DC5V±5% |
| ||
Output Circuits | Extracted through voltage division with a variable resistor | Total resistance of the variable resistor 10kQ±30% | ||
Driving Circuit | No | Color | Wiring | SET Necessary conditions for control program:
1.Detection of abnormal load: Power should be cut off if abnormal torque (TORQUE) is detected after the switch is turned on. 2.Drive speed control: Implement deceleration before full opening to prevent impact noise. |
1 | Red | MOTOR(-) | ||
2 | Black | MOTOR(+) | ||
3 | Red | GND | ||
4 | White | OUTPUT | ||
5 | Yellow | Vcc:DC5V | ||
Output Signal | Closing Position-5°: 0.85±0.25V Opening Position 125°:3.85±0.25V | This tolerance range refers to the signal output range of the limit position among different individuals under the standard supply voltage of 5V. |